All blasting machine purchases will require an End User Certificate (PDF) and you may also be asked for a copy of your credentials, if not already on file. Export Administration Regulations (EAR) & International Traffic in Arms Regulations (ITAR): These items are controlled by the U.S. government and authorized for export only to the country of ultimate destination for use by the ultimate consignee or end-user(s) herein identified. They may not be resold, transferred, or otherwise disposed of, to any other country or to any person other than the authorized ultimate consignee or end-user(s), either in their original form or after being incorporated into other items, without first obtaining approval from the U.S. government or as otherwise authorized by U.S. law and regulation If you are purchasing this item, please either complete an EUC by navigating to the 'Other information' tab above, OR use the contact-us form to request a pre-filled EUC which you can sign and return.
 
SCORPION BTS-SBS

*** This unit is CE Marked and Certified.  This means that it has been tested by the manufacturer and it meets CE Certification requirements.


FEATURES:
- SOLID STATE ELECTRONIC
- CAPACITOR DISCHARGE BLASTING UNIT
- NON-ELECTRIC SHOCK TUBE INITIATOR
- CONTINUITY TEST LIGHT
- CAPACITY UP TO 50 CAPS

Mechanical:

Case Material: H.D. Urethane
Case Size: 3"W x 2"D x 6"H
7.6cm W x 5.8cm D x 15.2cm H
Weight: 1 lbs. 12 oz. (0.79 kg)
Shipping Weight: 3 lbs. (1.5 kg)

Electrical:

Type of Circuitry: Solid State Electronic
Firing Control Circuit: SCR (silicon controlled rectifier)
Firing Voltage: 225 VDC Minimum
Firing Energy: 4.0 Joules (w/s)
Power Source: 1 Ea. 9V Alkaline Dry Cell ('AA' Cells, NEDA 15A)
Battery Voltage: 1 x 9V
H.V. Source: Inverter, Solid State Electronic
Energy Storage: Capacitor, Special Electrolytic, H.D.

Capacity:

Non-Electric Initiator: 1 Non-Electric Lead In
Straight Series: 50 - 2 Ohm Electric Blasting Caps
Series Parallel: 2 Series of 25 - 2 Ohm Electric Blasting Caps
Max. Ohms @ 1.5 Amperes & 0.025 Joules / Ohm Circ. Res.: 135 Ohms

Output:

Vertical: 45 VDC / Div.
Horizontal 1 (green): 0.1 ms / Div.
Horizontal 2 (yellow): 1.0 ms / Div.


Operating Manual:

SCORPION HB-SBS
SOLID STATE ELECTRONIC BLASTING UNIT
& NON-ELECTRIC SHOCK TUBE INITIATOR
Section I - Mechanical
Case Material: Heavy Duty Urethane
Case Size: 3"W x 2"D x 6"H (7.6cm W x 5.8cm D x 15.2cm H)
Weight: 1 lbs. 12 oz. (0.79 kg)
Type Circuitry: Solid State Electronic
Firing Voltage: 225 VDC Minimum (Nominal)
Firing Energy: 4 Joules (w/s)
Power Source: 1 Ea. 9V Alkaline Dry Cell (NEDA 15A)
Section II - Operating Procedures
TO TEST: Before connecting to blasting circuit; depress "CHARGE" switch
until "READY" light illuminates. While maintaining pressure on "Charge"
switch depress "DETONATE" switch. "READY" light should go off immediately.

Caution: Do NOT relax "Charge" switch when depressing "Detonate" switch.
The HB-SBS utilizes a dual switch firing mechanism to assure the blaster's
conviction to detonate.

When "READY" light fails to illuminate replace the 4 'AA' Alkaline
Cells under battery cap on right side of machine. Observe cap position when
replacing cap so as not to cross thread.

TO OPERATE: Connect machine to the blasting circuit and repeat "CHARGE"
and "DETONATE" sequence as in "TO TEST."

Section III - Handling & Care
To maintain the proper functionality of your Scorpion HB-SBS Blasting unit
please observe the following:
a. Avoid severe impact. The HB-SBS is impact resistant however
severe localized or blunt impact could crack and/or breach
the HB-SBS's casing. NEVER USE THIS UNIT IF ITS CASE IS
CRACKED OR BREACHED. In this instance please see
Section V - Servicing.
b. Avoid leaving the HB-SBS partially or fully submerged in water.
should your HB-SBS become partially or fully submerged in
water towel dry the machine including switch and binding
posts. Should battery corrosion occur refer to Section V
- Servicing.
c. Avoid wrenching, impacting, or over-tightening binding posts.
Should this happen to the binding posts the protective
plastic shielding may become damaged or removed. SHOCK
HAZARD: If the protective plastic shielding is removed from
one or both of the binding posts potentially lethal voltage
exists to a grounded blaster should contact be made with the
exposed binding post at discharge. See Section V
- Servicing for maintenance and repair information.
d. After daily use clear debris and/or dust from in and around
switch bezel and store it in a safe and dry environment.
e. NEVER use your HB-SBS as a lever or impact device.
f. NEVER use your HB-SBS as an alternate energy source on equipment
for which it was not designed.
g. Output oscillograms are recorded on every machine by the
manufacturer.
h. NEVER USE A DAMAGED OR QUESTIONABLE MACHINE.

Section IV - Labeling
The HB-SBS's face plate includes operating instructions and the unit's
serial number. Should this label become unlegible or is removed
see Section V - Servicing for replacement.