HB500 SINGLE CIRCUIT MACHINE

$949.75
Item
72910
HB500 SINGLE CIRCUIT MACHINE
*** Due to the delay by the manufacture this item may a long lead time.  Please contact us before processing your order to confirm availability or to get information about an alternative item.  You can contact us 800-634-6250 or 502-859-3850.  Thank you and we do apologize for the inconvenience, we do want to make you aware of the situation before you place your order. ***

SCORPION HB-500

SOLID STATE ELECTRONIC
CAPACITOR DISCHARGE BLASTING UNIT









Mechanical:
Case Material: H.D. Urethane
Case Size: 6"W x 2"D x 9"H
15.24cm W x 5.8cm D x 22.86cm H
Weight: 4 lbs. (1.82 kg)
Shipping Weight: 6 lbs. (2.72 kg)

Electrical:
Type of Circuitry: Solid State Electronic
Firing Control Circuit: SCR (silicon controlled rectifier)
Firing Voltage: 445 VDC Minimum
Firing Energy: 35 Joules (w/s)
Power Source: 4 Ea. 1.5V Alkaline Dry Cells ('D' Cells, NEDA 13A)
Battery Voltage: 4 x 1.5V (6V Total)
H.V. Source: Inverter, Solid State Electronic
Energy Storage: Capacitor, Special Electrolytic, H.D.

Capacity:
1 Series: of 100 - 2 Ohm Electric Detonators
2 Series: of 100 - 2 Ohm Electric Detonators
4 Series: of 90 - 2 Ohm Electric Detonators
7 Series: of 70 - 2 Ohm Electric Detonators
10 Series: of 50 - 2 Ohm Electric Detonators
12 Series: of 40 - 2 Ohm Electric Detonators
12 Series: of 30 - 2 Ohm Electric Detonators
Max. Ohms @ 1.5 Amperes & 0.025 Joules / Ohm Circ. Res.: 280 Ohms

Output:

OSCILLOGRAM IMAGE

Vertical: 84 VDC / Div.
Horizontal 1 (green): 0.1 ms / Div.
Horizontal 2 (yellow): 1.0 ms / Div.

Comparative Machines:

HB-320, HBR-350

Operating Manual:
SCORPION HB-500
SOLID STATE ELECTRONIC BLASTING UNIT
Section I - Mechanical

Case Material: Heavy Duty Urethane
Case Size: 6"W x 2"D x 9"H (15.24cm W x 5.8cm D x 22.86cm H)
Weight: 4 lb. (1.82 kg)
Type Circuitry: Solid State Electronic
Firing Voltage: 445 VDC Min.
Firing Energy: 35.0 Joule (w/s)
Power Source: 4 Ea. 1.5V Alkaline Dry Cells ('D' Cells, NEDA 13A)

Section II - Operating Procedures

TO TEST: Before connecting to blasting circuit; charge by pressing switch
to "CHARGE" position. When "READY" light illuminates press switch to
"DETONATE" position. "READY" light should go off immediately.

For the practical purposes of these instructions "READY WHEN FULLY LIT"
is to indicate that the ready light be of singular and even luminesce
quality before pressing "DETONATE."

When "READY" light fails to illuminate replace the four (4) Alkaline 'D'
Cells under battery cover on back of machine. Observe polarity when
replacing cells and replace cover.

TO OPERATE: Connect machine to the blasting circuit and repeat "CHARGE"
and "DETONATE" sequence as in "TO TEST."

Section III - Handling & Care

To maintain the proper functionality of your Scorpion HB-500 Blasting unit
please observe the following:

a. Avoid severe impact. The HB-500 is impact resistant however
severe localized or blunt impact could crack and/or breach
the HB-500's casing. NEVER USE THIS UNIT IF ITS CASE IS
CRACKED OR BREACHED. In this instance please see
Section V - Servicing.
b. Avoid leaving the HB-500 partially or fully submerged in water.
should your HB-500 become partially or fully submerged in
water towel dry the machine including switch and binding
posts. Remove rear battery compartment cover and replace
the four (4) Alkaline 'D' cells to prevent possible battery
corrosion. Dry off inside battery compartment with a towel and
leave the machine in open air to dry. Should battery
corrosion occur refer to Section V - Servicing.
c. Avoid wrenching, impacting, or over-tightening binding posts.
Should this happen to the binding posts the protective
plastic shielding may become damaged or removed. SHOCK
HAZARD: If the protective plastic shielding is removed from
one or both of the binding posts potentially lethal voltage
exists to a grounded blaster should contact be made with the
exposed binding post at discharge. See Section V
- Servicing for maintenance and repair information.
d. After daily use clear debris and/or dust from in and around
switch bezel and store it in a safe and dry environment.
e. NEVER use your HB-500 as a lever or impact device.
f. NEVER use your HB-500 as an alternate energy source on
equipment for which it was not designed.
g. Output oscillograms are recorded on every machine by the
manufacturer. If you need a copy of these test traces
contact E.I.T. Corporation at (570) 286-7744. For annual
or biannual maintenance programs: Testing and output traces
are available by the manufacturer. See Section V - Servicing
for return information.
h. NEVER USE A DAMAGED OR QUESTIONABLE MACHINE. For repair and
servicing see Section V - Servicing.

Section IV - Labeling

The HBR-500's face plate includes operating instructions and the unit's
serial number. Should this label become unlegible or is removed
see Section V - Servicing for replacement.