HBR-20P (PERMISSIBLE) BLAST MACHINE
$779.63
Item
14916
All blasting machine purchases will require an End User Certificate (PDF) and you may also be asked for a copy of your credentials, if not already on file. Export Administration Regulations (EAR) & International Traffic in Arms Regulations (ITAR): These items are controlled by the U.S. government and authorized for export only to the country of ultimate destination for use by the ultimate consignee or end-user(s) herein identified. They may not be resold, transferred, or otherwise disposed of, to any other country or to any person other than the authorized ultimate consignee or end-user(s), either in their original form or after being incorporated into other items, without first obtaining approval from the U.S. government or as otherwise authorized by U.S. law and regulation If you are purchasing this item, please either complete an EUC by navigating to the 'Other information' tab above, OR use the contact-us form to request a pre-filled EUC which you can sign and return.
Mechanical:
Case Material: H.D. Urethane
Case Size: 3"W x 2"D x 6"H
7.6cm W x 5.8cm D x 15.2cm H
Weight: 1 lbs. 12 oz. (0.79 kg)
Shipping Weight: 3 lbs. (1.5 kg)
Electrical:
Type of Circuitry: Solid State Electronic
Firing Control Circuit: SCR (silicon controlled rectifier)
Firing Voltage: 350 VDC Minimum (Nominal)
Firing Energy: 6.125 Joule (w/s)
Shunt Circuit: SCR (silicon controlled rectifier)
Shunt Timing: 4.5 to 8 m/sec (Avg 6 m/sec)
Power Source: 4 Ea. 1.5V Alkaline Cells ('AA' Cells, NEDA 15A)
Battery Voltage: 4 x 1.5V (6V Total)
H.V. Source: Inverter, Solid State Electronic
Energy Storage: Capacitor, Special Electrolytic, H.D.
Capacity:
Per MSHA CFR-30, Part 25: 20 Iron Leg Wire (16') Electric Detonators (Short Delay) in a Single Series
Output:
OSCILLOGRAM TRACE
Typical Discharge
1) thru open circuit
2) thru 350 Ohms
3) thru 250 Ohms
4) thru 150 Ohms
5) thru 50 Ohms
V-60VDC/Div H-1ms/Div
Comparative Machines:
HB-20P, HB-20AP
Operating Manual:
SCORPION HBR-20P
SOLID STATE ELECTRONIC BLASTING UNIT
MSHA APPROVAL# 16E-15
Section I - Mechanical
Case Material: Heavy Duty Urethane
Case Size: 3"W x 2"D x 6"H (7.6cm W x 5.8cm D x 15.2cm H)
Weight: 1 lbs. 12 oz. (0.79 kg)
Type Circuitry: Solid State Electronic
Firing Voltage: 350 VDC Minimum (Nominal)
Firing Energy: 6.125 Joules (w/s)
Shunt Timing: 4.5 to 8 m/sec (Avg 6 m/sec)
Power Source: 4 Ea. 1.5V Alkaline Dry Cells ('AA' Cells, NEDA 15A)
Section II - Operating Procedures
TO TEST: Before connecting to blasting circuit; depress "CHARGE" switch
until "READY" light illuminates. While maintaining pressure on "Charge"
switch depress "DETONATE" switch. "READY" light should go off immediately.
Caution: Do NOT relax "Charge" switch when depressing "Detonate" switch.
The HBR-20P utilizes a dual switch firing mechanism to assure the blaster's
conviction to detonate.
When "READY" light fails to illuminate replace the 4 'AA' Alkaline
Cells under battery cap on right side of machine. Observe cap position when
replacing cap so as not to cross thread.
TO OPERATE: Connect machine to the blasting circuit and repeat "CHARGE"
and "DETONATE" sequence as in "TO TEST."
Section III - Handling & Care
To maintain the proper functionality of your Scorpion HBR-20P Blasting unit
please observe the following:
a. Avoid severe impact. The HBR-20P is impact resistant however
severe localized or blunt impact could crack and/or breach
the HBR-20P's casing. NEVER USE THIS UNIT IF ITS CASE IS
CRACKED OR BREACHED. In this instance please see
Section V - Servicing.
b. Avoid leaving the HBR-20P partially or fully submerged in water.
should your HBR-20P become partially or fully submerged in
water towel dry the machine including switch and binding
posts. Should battery corrosion occur refer to Section V
- Servicing.
c. Avoid wrenching, impacting, or over-tightening binding posts.
Should this happen to the binding posts the protective
plastic shielding may become damaged or removed. SHOCK
HAZARD: If the protective plastic shielding is removed from
one or both of the binding posts potentially lethal voltage
exists to a grounded blaster should contact be made with the
exposed binding post at discharge. See Section V
- Servicing for maintenance and repair information.
d. After daily use clear debris and/or dust from in and around
switch bezel and store it in a safe and dry environment.
e. NEVER use your HBR-20P as a lever or impact device.
f. NEVER use your HBR-20P as an alternate energy source on equipment
for which it was not designed.
g. Output oscillograms are recorded on every machine by the
manufacturer. If you need a copy of these test traces
contact E.I.T. Corporation at (570) 286-7744. For annual
or biannual maintenance programs: Testing and output traces
are available by the manufacturer. See Section V - Servicing
for return information.
h. NEVER USE A DAMAGED OR QUESTIONABLE MACHINE. For repair and
servicing see Section V - Servicing.
Section IV - Labeling
In accordance with MSHA regulations your HBR-20P must have a label which
clearly designates it as an MSHA approved Permissible Blasting Unit when
used in that capacity. Should this label become unlegible or is removed
see Section V - Servicing for replacement.
Write Your Own Review