Model 109 Blasters Multimeter
Modified for the blasting industry. The 109 Blasting Multimeter is designed for safe, precise circuit measurement when using electric detonators. It has a built-in current limiting circuit with current output less than 0.004 amps (4 miliamperes)
Current lead time: 6 weeks
Features: 3.5 digit LCD, 1999 count, 6k protection for all voltage & resistance ranges, 600v overload protection in all resistance ranges.
Weight: 20 oz. (.56kg)
Size: 3.9 x 7.2 x 2(99x182x51 mm)
Seal: Dust and Damp Weather Proof Weather Proof
MSHA Approved: NO
Ranges: 8 Range
Battery Type 9V NEDA 1604/1604A
Current Output: <4mA
The 109 is designed for professional use in harsh environments. The meter is unusually rugged and reliable in everyday heavy use applications. The meter is made using waterproof construction to prevent dirt, grime and moisture from entering the case and causing inaccurate readings or damaging shorts. Built of tough, fire-retardant thermoplastic resistant to grease and chemical spills, with all sensitive components shock-mounted for a drop resistant to at least eight feet.
The 109 has an extended voltage measurement capability of 1500 V dc and 1000 V ac, unmatched by any other line of digital multimeters. The extended voltage ranges can withstand transients up to 12 kV.
FEATURES |
|
DC Voltage | 200.0 mV, 2.000 V, 20.00 V, 200.0 V, 1500 V |
AC Voltage | 200.0 mV, 2.000 V, 20.00 V, 200.0 V, 1000 V |
Current | AC/DC 200.0 µA, 2.000 mA, 20.00 mA, 200.0 mA, 2 A |
Resistance | 200.0 O, 2.000 kO, 20.00 kO, 200.0 kO, 2.000 MO, 20.00 MO |
Specifications | |
DC Volts range: | 200 mV, 2 V, 20 V, 200 V, 1500 V |
DC Volts resolution: | 0.1 mV |
DC Volts accuracy: | All ranges ±(0.1 % rdg+2 dgts) |
DC Volts input impedance: | 10 MO |
DC Volts OL protection: | >1500 V DC/1000 V AC rms |
DC Volts transient protection: | >12 kV impulse (1.2 µS/50 µS) based on EN 61010-1:2001 impulse requirement for at CAT IV 1000 V product. This product should not be used in installations where transients exceed 12 kV |
AC Volts (45 Hz to 2 kHz) ranges: | 200 mV, 2 V, 20 V, 200 V, 1000 V |
AC Volts (45 Hz to 2 kHz) resolution: | 0.1 mV |
AC Volts (45 Hz to 2 kHz) accuracy: | 200 mV to 200 V (45-500 Hz) ±(0.8 % rdg+4 dgts), |
AC Volts (45 Hz to 2 kHz) accuracy: | 200 mV to 200 V (500 Hz-2 kHz) ±(1.5 % rdg+5 dgts) |
AC Volts (45 Hz to 2 kHz) accuracy: | 1000 V (50-60 Hz) ±(0.8 % rdg+4 dgts) |
AC Volts (45 Hz to 2 kHz) accuracy: | 1000 V (60-500 Hz) ±(1.5 % rdg+5 dgts) |
AC Volts (45 Hz to 2 kHz) input impedance: | 10 MO |
AC Volts (45 Hz to 2 kHz) OL protection: | 1500 V DC/1000 V AC rms |
AC Volts (45 Hz to 2 kHz) transient protection: | 12 kV impulse (1.2 µS/50 µS) based on EN 61010-1:2001 impulse requirement for at CAT IV 1000 V product. This product should not be used in installations where transients exceed 12 kV. |
DC Current range: | 200 µA, 2 mA, 20 mA, 200 mA, 2 A |
DC Current resolution: | 0.1 µA |
DC Current accuracy: | 200 µA to 20 mA ±(0.5 % rdg+2 dgts) |
DC Current accuracy: | 200 mA to 2 A ±(1.0 % rdg+2 dgts) |