720A2301,720A2001,720A1801 - Minimate Pro4 Base Unit: 4-Channel base unit with 64 megabytes of memory, ethernet RJ-45 cable, Blastware Compliance Module software, power adaptor, carrying case and electronic version of manual. Note: Please specify the req
$8,895.00
Item
69362
720A2301,720A2001,720A1801
- Minimate Pro4 Base Unit: 4-Channel base unit with 64 megabytes of memory, ethernet
RJ-45 cable, Blastware Compliance Module software, power adaptor, carrying case and
electronic version of manual.
Note: Please specify the required power adaptor, 110V AC North American or 220V
international, at the time of order.
Minimate Pro ISEE 2 m (6.5 ft) Triaxial Geophone: 2-250 Hz geophone. Comes complete
with a 2 m (6.5 ft) cable and mounting spikes (p/n 1100241).
Minimate Pro Linear Microphone: Measures air overpressure in a linear scale. Comes
complete with 2 m (6.5 ft) cable and microphone stand (p/n 720A6001).
MM Pro4 Minimate Pro4 System: Base unit (p/n 720A2301)with 64 Megabytes of Memory, Standard
Triaxial Geophone with 2 m (6 ft.) cable (p/n 720A2001), Linear Microphone Assembly (p/n
720A1801), Ethernet cable RJ-45, Blastware® Compliance Module Software, 110V AC power
adaptor, manual and carrying case (p/n 72002101)
The Series IV Minimate Pro4 vibration and overpressure monitor offer advanced monitoring technology with unequalled durability.
- Four recording channels for one triaxial geophone (ISEE or DIN) and an ISEE linear microphone.
- Dedicated function keys and intuitive menu enable quick and easy setup.
- Sample rates from 512 to 65 S/s per channel, independent of record times.
- Continuous monitoring means zero dead time between events, even while the unit is processing.
- Instantel Histogram Combo mode allows capturing thousands of full waveform records while recording in histogram mode.
- Auto Call Home feature automates remote monitoring applications.
- Non-volatile memory with standard 8000-plus event storage capacity.
- Records full waveform events over two hours long.
- Fully compliant with the International Society of Explosives Engineers "Performance Specifications for Blasting Seismographs."
- Ethernet® interface for high speed communications and data transfer. (Auto Call Home is not supported over the Ethernet)
Range of Applications
- 4-Channel data acquisition
- Blast-monitoring for compliance
- Pile driving
- Construction activity
- Demolition activitiy
- Remote monitoring